Diagnostic Tags for Collectors
We have recently setup event monitoring for diagnostic tags in our environment which is working great. We are currently troubleshooting an issue with spiking high CPU use on one of our Cygnet…
-
Allow Store and Forward Buffer disk location to be changed
Store & Forward Buffer location is fixed on: C:\ProgramData\Canary\StoreAndForward\Buffer While I understand the Buffer Disk Space Limit can be set to hopefully minimize the chance of running the…
-
Bulk remove Calculations
Is there an easy way to remove multiple Calculations at once? Or is the only way to click delete on each one individually?
- Answered
-
How to Add an OpenID Connect Identity Provider (version 25)
By default, Canary uses Windows AD for user authentication; however, Canary also supports OAuth 2.0/OpenID Connect. This gives end users alternate options for signing into Canary's application tools…
-
Scatter Plot Control (version 25)
Properties *Name - a unique name used to reference the control in script AggregateInterval - the amount of time within each interval over which the data is processed using an AggregateKind (e.g.…
-
Most efficient way to export large volumes of data with API
I’m working with a customer who needs about six months of historical data at a 10-second resolution for approximately 1,200 tags. I'm writing a script using continuation to retrieve the data,…
-
Geo SCADA Collector: Make Startup Faster
The Geo SCADA Collector tags a really long time to start up. One group we work with it takes 30 or 45 minutes to start up depending on the system. Can we look at ways to speed this up.…
-
Geo SCADA Collector: Create Canary tag with GS ID
When the Geo SCADA Collector (like most other collectors), it creates a Canary tag based on the tag path in GS. For example File.Station.Equipment.Pressure.…
-
Geo SCADA Collector: Filter Tags by Property
In v 25.1 of the Geo SCADA Collector, you can set root folders to search and you can now filter tags (include and exclude) using RegEx. It would be nice if you could filter by metadata properties.…
-
Audit - Recording "Local Client" as the user who made a change on a calculation
Hello! When I am creating a calculation and have enhanced audit enabled, I can see that the audit recorded an ADD message with a timestamp and the user name who made the changes (me in this case).…
- Acknowledged
-
Increased resolution for png files created by automated reports
Automated reports (How To Create an Automated Report in Axiom (version 25) - General - Canary Community) generate two files: a .pdf and a .png file each are snapshots of an Axiom chart.…
-
Add Asset Selection Between Application Tabs
When you have an Asset Selector and multiple tabs on an Application, the Asset is not remembered or shared between the tabs. You could be on Asset 1 in tab 1 and Asset 5 on tab 2.…
-
Axiom Panel Visible at certain times and blinking panel
I am making a dashboard and I am wanting to have a panel that is only visible at certain times of the day and then turns invisible outside that period of time.…
-
Release V25.3
REQUEST UPGRADE Built on Windows Server 2019 Standard MSBuild v17.0 MSI: Wix v1.14.2 Released on: 6/9/2025 If .NET Framework 4.7.1 or greater is not present on the system,…
-
Sender can only connect anonymously, cannot connect secure.
Hello, We have multiple ignition senders connected to 1 historian server. All of the sender services are using ignition collectors and they are all configured the same.…
-
MQTT Collector logs only DBIRTH
Hello, I have modified the python script available in tahu-master python-examples-example.py to test the MQTT collector (23.2.1). The broker I am using is mosquitto.…
-
/getLiveData timestamps
I am reading live data of tags that are in the same group and have a sample time of 1 sec in the OPC collector. When I read the live data I get some .5 second intervals (which seems odd since the OPC…
-
Ignition Module - Obsolete Tag Function
There is an obsolete function available in the write API from v25.3. It would be great if this functionality is wrapped in the Ignition module and exposed as a system function.…
-
Obsolete API Endpoint
I'm currently using canary with ignition and have found the process of removing tags from canary inconvenient. The current canary ignition module does not have any ability to remove a tag from canary…
- Released
-
Using a TLS Certificate for Canary Services (version 24)
By default, Canary generates a self-signed certificate for its services that require a secure encrypted connection. This certificate, however, is not a trusted certificate.…
-
Data Entry Control in Asset Template should indicate tag doesn't exists
In Axiom v24, if you add a Data Entry Control to an Asset Template, the control will show up in each asset pane, regardless of whether or not that tag exists.…
- Fixed
-
Axiom v24 Calculated Trends Don't Update if Source Tag is Missing (Asset Template)
I simplified the user case for purposes of explanation. We have an Asset Type of "Well". Most Wells have a tag called "Oil Rate". Some do not. We have an Application with the Screen configured with…
- Fixed
-
Clicking on Events table n Axiom to open a display for the selected event
I'm trying and failing to do this using scripting in Axiom but maybe there's another way to do what I want (I'm running Canary V25.1)? What I wanted was, within Axiom,…
-
Scatter Plot Control (version 24)
Properties *Name - a unique name used to reference the control in script AggregateInterval - the amount of time within each interval over which the data is processed using an AggregateKind (e.g.…
-
How To Filter Asset Templates and Grids (version 24)
Both asset templates and grids have a TemplateFilter property that can be used to filter assets based on tag values, tag names, asset names, tag properties, and/or value qualities.…