-
Ignition Module system.tag.browseHistoricalTags()
Is there a way to use Ignition's system.tag.browseHistoricalTags() function with the Canary module as the history provider? I'm thinking there must be, as the Power Chart successfully populates the…
-
Release V24.0.2
Requires Ignition 8.1.5 Released on: 10/23/2024 Features Normalized Ignition tag quality subcodes to standard OPC quality values
-
Release V24.0.1
Requires Ignition 8.1.5+ Released on: 10/14/2024 Features Support for Canary v24 Bugs Adjusted returnSize settings to ensure Min/Max calls are not requesting "raw data" to ensure the aggregate was…
-
Module Download and Installation Instructions (version 24)
Latest tested and supported version of Ignition: 8.1.43 If using 8.1.31 or 8.1.32, the provider name must match the collector name. A bug was introduced in 8.1.31 (and fixed in 8.1.…
-
Changing Tag (from Ignition project) name before entering Canary Historian
We've got existing systems that did not use historian database capabilities and I am introducing the concept to the business units. I understand the concept of data historians,…
-
Deleting Collectors Doesn't Work
When a Canary Collector is deleted, the version 23.0.0 Canary Historian Module does not delete/unregister the store and forward sink associated with the Canary Collector.…
-
Obsolete API endpoint feature
I'm currently using canary with ignition and have found the process of removing tags from canary inconvenient. The current canary ignition module does not have any ability to remove a tag from canary…
-
How to write to Canary from Ignition using script
Hi, I am trying to write to Canary using the following code but it is not being written into and Ignition is also not throwing an error, can somoen help.…
-
Release V23.0.1
Requires Ignition 8.1.5+ For full functionality, this version requires Canary V23.0+ for getTagContext Views API endpoint but will function without it. Released on:…
-
Module Download and Installation Instructions (pre-24 version)
Latest tested and supported version of Ignition: 8.1.43 If using 8.1.31 or 8.1.32, the provider name must match the collector name. A bug was introduced in 8.1.31 (and fixed in 8.1.…
-
No option for "includeBounds" in Ignition module.
Hi, I am using the Ignition module, but there does not appear to be any option to "includeBounds" as there is in the web API (see the above images). Neither setting "includeBoundingValues" to True,…
- Fixed
-
Release V23.0.0
Requires Ignition 8.1.5+ Released on: 8/2/2023 Features Changed the name of the Sender sessions from "Ignition API" to the Canary Collector name and "Ignition API".…
-
Ignition Tag Latency in Canary Historian
I'm currently having issues with canary reading the correct tag values. I previously had this working at one point in time before all my servers got reset.…
-
Release V22.3.3
Requires Ignition 8.1.5+ Released on: 5/3/2023 Bug Fixes Fixed issue with reading Boolean tag history.
-
Inconsistent Vector Size When Writing Historical Data
Hey Guys, I'm fairly new to Canary, and I'm struggling to understand how Vectors work. The only documentation I found says the Vector size should be based on data type.…
-
Release V22.3.2
Released on: 4/5/23 Ignition Version: 8.1.5+ Bug Fixes Fixed issue with properties getting sent to multiple collectors
-
Release V22.3
Released on: 2/6/23 Ignition Version: 8.1.5+ Features Updated to use the Canary API getTagData2 function
-
Release V22.2
Released on: 1/9/23 Ignition Version: 8.1.5+ Features Support for providing string tags back to Ignition Bug Fixes Tag history calculations for multiple tags works correctly now Good backfill history…
-
Release V22.1.1
Released on: 8/8/2022 Ignition Version: 8.1.5+ Bug Fixes Change LastValue Ignition aggregate to map to End instead of EndBound aggregate
-
How to Configure the Ignition Collector (version 22)
Begin Logging Ignition Data Created by Inductive Automation, Ignition is a software platform that acts as an HMI, SCADA System, and MES. The Canary Module for Ignition can be used to both write data…
-
How to Configure the Ignition Collector (version 23)
Latest tested and supported version of Ignition: 8.1.36 If using 8.1.31 or 8.1.32, the provider name must match the collector name. A bug was introduced in 8.1.31 (and fixed in 8.1.…
-
How to Configure the Ignition Collector (version 24)
If using 8.1.31 or 8.1.32, the provider name must match the collector name. A bug was introduced in 8.1.31 (and fixed in 8.1.33) that prevented the module from working properly without the names…
-
Release V22.1.0
Released on: 4/29/2022 Ignition Version: 8.1.5+ Bug Fixes Properties not getting stored when using the Collector in conjunction with a Tag Splitter A secure connection through the Canary Provider…
-
Integrating Canary with Ignition: Enterprise Applications
Learn how to use the Canary Historian as the default historian for an Ignition SCADA project. With a focus on enterprise applications, you will learn how to log data to Canary site and enterprise…
-
Ignition Integration - Part 1 (v21)
Topics covered in this coaching session include: Where to download Canary's Module for Ignition SCADA How to configure Ignition to historize data to a Canary Historian Demonstration of how to read…